MIL-PRF-19500/116S
TABLE I. Group A inspection - Continued.
MIL-STD-750
Limit
Inspection 1/ 2/ 3/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 4 - Continued
Condition A, C ≥ 1 nF,
trr
Reverse recovery time
4031
5
ns
IF = IR = 10 mA dc,
RL = 100Ω ±5 percent,
IR(REC) = 1.0 mA dc,
R ≥ 1,000 Ω
Method 4023 of MIL-STD-750,
Scope display evaluation
4023
figures 4023-3, 4023-7,
4023 -9,4023 -10 only
Subgroup 5
Not applicable
Subgroup 6
Surge current
4066
Condition A (sine wave),
IF(surge) = 2 A(pk), IO = 0,
VRM = 0, 10 surges,
8.3 ms width each, one surge
per minute, TA = +25°C
or
Condition B (square wave),
IF(surge) = 4 A (pk),
10 surges, 1µs width each,
duty factor = 0.0055 percent,
TA = 25°C
See table I, subgroup 2
Electrical measurements
Subgroup 7
IF = 50 mA dc
Vpeak
Forward recovery
4026
5.0
V (pk)
voltage and time
20
ns
tfr
(see 4.5.1)
1/ For sampling plan, see MIL-PRF-19500.
2/ UB-suffix devices are to have each diode tested individually.
3/ Electrical characteristics for surface mount versions are identical to the corresponding axial leaded versions
unless otherwise specified.
15
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business