MIL-PRF-19500/246K
4.5 Methods of inspection. Methods of inspection shall be as specified in the appropriate tables as follows.
4.5.1 Power cycling. One complete test shall be as follows: First, heat the case to the maximum temperature
specified by passing the specified amount of forward current through the diode under test. Then, remove the applied
current and allow the case temperature to cool to the minimum case temperature specified. No time limit is
applicable to any one cycle, but the cycling shall be continuous until the required number of cycles have been
completed. Sample size = 12, c = 0.