MIL-PRF-19500/436A
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for subgroup testing in
table VII of MIL-PRF-19500, and as follows. Electrical measurements (endpoints) shall be in accordance with the applicable footnotes
and steps of table III herein.
Subgroup
Method
Condition
C2
2036
Terminal strength: test condition A; 4 lbs, t = 15 sec.
Lead fatigue, test cond. E.
VR = 25 V dc, TA = 150°C, t = 1000 hrs.
C6
1027
4.4.4 Temperature coefficient of capacitance. Throughout the temperature range specified the capacitance shall not change by more
than .04 %/°C relative to the capacitance value measured at TA = 25°C. The temperature coefficient of capacitance may be computed by
the following formula:
2
TCC =
CT (+85°C) - CT (-65°C)
10
---------------------------------
X
-------
CT (25°C)
85 + 65
(Accuracy is limited by the CT measurement to ± 0.1 pF.)