MIL-PRF-19500/436A
TABLE III. Electrical end-point measurements.
Step
Inspection
MIL-STD-750
Symbol
Limits
Unit
Method
Details
Min
Max
1.
Reverse current
4016
20
nA dc
VR = 25 V dc;
IR1
dc method
2.
Capacitance
4001
C
Col. 3 of
Col. 4 of
pF
VR = 4 V dc; f = 1 MHz
table II
table II
1/ The electrical measurements for table VIb (JAN, JANTX, and JANTXV) of MIL-PRF-19500 are as follows:
a. Subgroups 2, 3, and 6, see table III herein, steps 1 and 2.
2/ The electrical measurements for table VII of MIL-PRF-19500 are as follows:
a. Subgroup 2, 3, and 6, see table III herein, steps 1 and 2.