MIL-PRF-19500/464G
* TABLE II. Group E inspection (all quality levels) - for qualification or re-qualification only.
Inspection
MIL-STD-750
Sample
plan
Method
Conditions
Subgroup 1
45 devices
c=0
Temperature cycling
1051
Test condition C, 500 cycles.
Hermetic seal
1071
Fine leak
Test conditions G or H
Gross leak
Test conditions C or D
Electrical measurements
See table I, subgroup 2 herein.
Subgroup 2
45 devices
c=0
Test temperature = +125°C; VCB = 30 V dc; T =
Blocking life
1048
1,000 hours.
Electrical measurements
See table I, subgroup 2 herein.
Subgroup 4
Thermal impedance curves
See MIL-PRF-19500.
3 devices
Subgroup 6
ESD
1020
Subgroup 8
45 devices
c=0
Reverse stability
1033
Condition B.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business