MIL-PRF-19500/198E
TABLE I. Group A inspection - Continued.
Limits
MIL-STD-750
Inspection 1/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 2 - Continued
μA dc
10
IKG
VCG = 5 V dc, anode open
4219
Reverse gate current
IG = -150 μA dc, VAA = 5 V dc
Holding current
IH
4201
0.3
5
mA dc
Subgroup 3
TA = +125°C
4206
High temperature
operation:
μA dc
Forward blocking
4206
R2 = 1,000 ohms
IFBX
100
current
2N1870A
VFBX = 30
2N1871A
VFBX = 60
2N1872A
VFBX = 100
2N1874A
VFBX = 200
μA dc
Reverse blocking
4211
R2 = 1,000 ohms
IRBX
100
current
2N1870A
VFBX = 30
2N1871A
VFBX = 60
2N1872A
VFBX = 100
2N1874A
VFBX = 200
V2 = VFBX = 5 V, Re = 1,000 Ω
Gate trigger voltage
4221
VGT
0.2
V dc
RL = 100 Ω
IG = -150 μA dc, VAA = 5 V dc
Holding current
4201
IH
0.2
mA dc
TA = -65°C
Low temperature
operation:
Gate trigger voltage
4221
V2 = VFBX = 5 V
VGT
1.0
V dc
Re = 1,000 Ω
RL = 100 Ω
μA dc
V2 = VFBX = 5 V, Re = 1,000 Ω
500
Gate trigger current
4221
IGT
RL = 100 Ω
IG = -150 μA dc, VAA = 5 V dc
4201
IH
15
mA dc
Holding current
See footnote at end of table.
7