MIL-PRF-19500/211D
TABLE II. Groups A, B, C, and E electrical measurements. 1/ 2/ 3/
Step
Inspection
Symbol
Limits
Unit
Method
Conditions
Min
Max
1.
Forward voltage
4011
Pulse method:
1.55
V (pk)
VFM
IFM = 940 A (pk);
pulse width = 8.3 ms maximum;
duty cycle = 2 percent maximum
2.
Reverse current
4016
AC method:
IRM1
1N3164, R
VRM = 200 V (pk)
10
mA (pk)
VRM = 400 V (pk)
1N3168, R
10
mA (pk)
VRM = 600 V (pk)
1N3170, R
10
mA (pk)
VRM = 800 V (pk)
1N3172, R
10
mA (pk)
VRM = 1,000 V (pk)
1N3174, R
10
mA (pk)
VRM = 1,200 V (pk)
1N3175, R
10
mA (pk)
VRM = 1,400 V (pk)
1N3176, R
10
mA (pk)
VRM = 1,600 V (pk)
1N3177, R
10
mA (pk)
ĆVFM
3.
Forward voltage
4011
IFM = 940 A (pk)
+0.1
V (pk)
(change)
The electrical measurements for table E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500 are as follows:
1/
a. Subgroup 2, see table II herein, steps 1 and 2.
b. Subgroup 3, see table II herein, steps 1, 2, and 3.
c. Subgroup 6, see table II herein, steps 1 and 2.
2/ The electrical measurements for table E-VII (all quality levels) of MIL-PRF-19500 are as follows:
a. Subgroup 2, see table II herein, steps 1 and 2.
b. Subgroup 5, see table II herein, step 2 during test.
c. Subgroup 6, see table II herein, steps 1, 2, and 3.
3/ The electrical measurements for table E-IX of MIL-PRF-19500 are as follows:
a. Subgroup 1, see table II herein, steps 1, 2, and 3.
b. Subgroup 2, see table II herein, steps 1, 2, and 3.
9