MIL-PRF-19500/375J
TABLE I. Group A inspection - Continued.
Inspection 1/
Limit
Unit
Method
Conditions
Symbol
Min
Max
Subgroup 3 - Continued
TA = -55°C
Low-temperature operation:
Small-signal, common-
3455
VDS = 15 V dc; VGS = 0;
|yfs|2
source, short-circuit, forward
f = 1 kHz; pulsed (see 4.5.1)
transadmittance
µS
2N3821, 2N3821UB
6,750
µS
2N3822, 2N3822UB
9,750
µS
2N3823, 2N3823UB
9,750
Subgroup 4
Small-signal common-
3453
VDS = 15 V dc; VGS = 0;
|yos|
source, short-circuit, output
f = 1 kHz; pulsed (see 4.5.1)
admittance
µS
2N3821, 2N3821UB
10
µS
2N3822, 2N3822UB
20
µS
2N3823, 2N3823UB
35
Small-signal common-
3431
6
pF
VDS = 15 V dc; VGS = 0;
Ciss
100 kHz ≤ f ≤ 1 MHz
source, short-circuit, input
capacitance
Small-signal common-
3453
VDS = 15 V dc; VGS = 0;
Crss
100 kHz ≤ f ≤ 1 MHz
source, short-circuit,
reverse-transfer capacitance
2N3821, 2N3821UB,
3
pF
2N3822, 2N3822UB
2N3823, 2N3823UB
2
pF
Small-signal common-
3455
VDS = 15 V dc; VGS = 0
|yfs|3
source, short-circuit, forward
transadmittance
µS
2N3821, 2N3821UB
f = 100 MHz
1,500
µS
2N3822, 2N3822UB
f = 100 MHz
3,000
µS
2N3823, 2N3823UB
f = 200 MHz
3,200
Small-signal common-
VDS = 15 V dc; VGS = 0; f = 200
gis
source, short-circuit, input
MHz; (see 4.5.3)
conductance
µS
2N3823 and 2N3823UB
800
only
See footnote at end of table.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business