MIL-PRF-19500/466C
* TABLE III. Group E inspection (all quality levels) for qualification and re-qualification only.
Inspection
MIL-STD-750
Sample
Plan
Method
Conditions
45 devices
Subgroup 1
c=0
Temperature cycling
1051
500 cycles minimum
Hermetic seal
1071
Fine leak
Gross leak
Electrical measurements
See table I, subgroup 2 and table II herein.
Subgroup 2
45 devices
c=0
Test temperature = +125°C; VCB = 80 percent of rated;
Blocking life
1048
T = 1,000 hours.
Electrical measurements
See table I, subgroup 2 and table II herein.
Subgroup 4
Sample size
N/A
Thermal impedance curves
See MIL-PRF-19500.
Subgroup 6
3 devices
ESD
1020
Testing is not required for class 3 listing. Testing is
required for a nonsensitive listing to prove capability.
Subgroup 8
45 devices
c=0
Reverse stability
1033
Condition B.
11