MIL-PRF-19500/466C
* TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Symbol
Limit
Unit
Method
Conditions
Min
Max
Subgroup 2 - Continued
Forward-current
3076
VCE = 2 V dc, IC = 5 A dc,
hFE1
30
transfer ratio
pulsed (see 4.5.1)
Forward-current
3076
VCE = 2 V dc, IC = 25 A dc,
hFE2
15
60
transfer ratio
pulsed (see 4.5.1)
Forward - current
3076
VCE = 5 V dc, IC = 50 A dc,
hFE3
5
transfer ratio
pulsed (see 4.5.1)
Subgroup 3
TA = +150°C
High-temperature
operation
µA dc
Collector - emitter
3041
Bias condition A,
ICEX2
50
cutoff current
VBE = 1.5 V dc
2N5683
VCE = 60 V dc
2N5684
VCE = 80 V dc
TA = -55°C
Low-temperature
operation
Forward - current
3076
VCE = 2.0 V dc,
hFE4
7
transfer ratio
IC = 25 A dc,
pulsed (see 4.5.1)
Subgroup 4
Pulse response:
3251
Test condition A except
test circuit and pulse
requirements per
figures 2 and 3 herein.
µs
Turn - on time
VCC = 30 V dc,
ton
1.5
IC = 25 A dc, IB1 = 2.5 A dc
µs
Turn - off time
VCC = 30 V dc,
toff
3.0
IC = 25 A dc,
IB1 = IB2 = 2.5 A dc
µs
Storage time
VCC = 30 V dc,
ts
2.0
IC = 25 A dc,
IB1 = IB2 = 2.5 A dc
See footnotes at end of table.
8
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business