MIL-PRF-19500/588A
TABLE III. Groups A, B, C, and E electrical end-point measurements. 1/ 2/ 3/
Step
Inspection
MIL-STD-750
Symbol
Limits
Unit
Method
Conditions
Min
Max
600
V dc
1.
Breakdown voltage
3407
VGE = 0,
V(BR)CES
collector to emitter
IC = 1.0 mA,
bias condition C
2.
Gate to emitter voltage
3403
3.0
5.5
V dc
VCE
VGE,
VGS(th)1
(threshold)
IC = 0.25 mA
100
nA dc
3.
Gate current
3411
VGE = 20 V,
IGES
VCE = 0,
bias condition C
-100
nA dc
Gate current
3411
VGE = -20 V,
IGES
VCE = 0,
bias condition C
250
A
4.
Collector current
3413
VGE = 0,
ICES
bias condition C,
VCE = 80 percent of
rated VCE
3.0
V
5.
Static collector to emitter
3405
VGE = 15 V,
VCE(on)1
on-state voltage
condition A,
pulsed (see 4.5.1),
IC = IC1
3.25
V
6.
Static collector to emitter
3405
VGE = 15 V,
VCE(on)2
on-state voltage
condition A,
pulsed (see 4.5.1),
IC = IC1
7.
Thermal response
3101
0.65
C/W
See 4.5.4, tH = 75 ms
Z JC
1/ The electrical measurements for appendix E, table VIa (JANS) of MIL-PRF-19500 are as follows:
a.
Subgroups 3 and 4, see table III herein, steps 1, 2, 3, 4, 5, and 6.
b.
Subgroups 5 and 6, see table III herein, steps 1, 2, 3, 4, 5, 6, and 7.
2/ The electrical measurements for appendix E, table VIb (JANTX and JANTXV) of MIL-PRF-19500 are as follows:
Subgroups 2 and 3, see table III herein, steps 1, 2, 3, 4, 5, and 6.
3/ The electrical measurements for appendix E, table VII of MIL-PRF-19500 are as follows:
Subgroups 2, 3, and 6, see table III herein, steps 1, 2, 3, 4, 5, 6, and 7.
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business