MIL-PRF-19500/622D
TABLE II. Group E inspection (all quality levels) for qualification or requalification only.
MIL-STD-750
Inspection
Qualification
inspection
Method
Conditions
45 devices
Subgroup 1
c=0
Temperature cycling
1051
500 cycles.
Hermetic seal
1071
Electrical measurements
See table I, subgroup 2.
Subgroup 2
45 devices
c=0
High temperature
1039
Condition A; 1,000 hours.
reverse bias
Electrical measurements
See table I, subgroup 2.
Subgroup 4
Thermal impedance curves
See MIL-PRF-19500.
Subgroups 5 and 6
Not applicable
Subgroup 8
45 devices
c=0
Reverse stability
1033
Condition B.
10