MIL-PRF-19500/622D
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-IX of MIL-PRF-19500 and as specified in table II herein. Electrical measurements
(end-points) shall be in accordance with table I, subgroup 2 herein.
4.5 Method of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows:
4.5.1 Pulse measurements. Conditions for pulse measurement shall be as specified in section 4 of
MIL-STD-750.
4.5.2 Thermal resistance. Thermal resistance measurements shall be conducted in accordance with test method
3131 of MIL-STD-750. The following details shall apply:
a.
Collector current magnitude during power application shall be 1.0 A dc.
Collector to emitter voltage magnitude shall be ≥ 10 V dc.
b.
c.
Reference temperature measuring point shall be the case.
Reference point temperature shall be +25°C ≤ TR ≤ +75°C and recorded before the test is started.
d.
e.
Mounting arrangement shall be with heat sink to header.
Maximum limit of RθJC shall be 1.5°C/W.
f.
7