MIL-PRF-19500/622D
TABLE I. Group A inspection - Continued.
MIL-STD-750
Limits
Symbol
Unit
Inspection 1/
Method
Conditions
Min
Max
Subgroup 4
Switching parameters
µs
Pulse delay time
See figure 4
td
0.2
µs
Pulse rise time
See figure 4
tr
1.3
µs
Pulse storage time
See figure 4
ts
1.4
µs
Pulse fall time
See figure 4
tf
1.2
Magnitude of small-
3306
VCE = 10 V dc; IC = 0.5 A dc;
|hfe|
4.0
20
signal short-circuit
f = 1 MHz
forward-current
transfer ratio
Open circuit output
3236
VCB = 10 V dc; IE = 0;
Cobo
500
pF
capacitance
f = 100 kHz to 1 MHz
Subgroup 5
TC = +25°C; t ≥ 1 s; 1 cycle;
Safe operating area
3051
(continuous dc)
(see figure 5)
Test 1
VCE = 11.5 V dc; IC = 10 A dc
Test 2
VCE = 45 V dc; IC = 2.5 A dc
Test 3
VCE = 60 V dc; IC = 0.9 A dc
TA = +25°C; IC = 10 A dc;
Safe operating area
3053
(clamped inductive)
VCC = 11.5 V dc; (See figures 6 and 7)
Clamp voltage = 80 V dc
Electrical measurements
See table I, subgroup 2
Subgroups 6 and 7
Not applicable
1/
For sampling plan see MIL-PRF-19500.
9