MIL-PRF-19500/626A
TABLE I. Group A inspection.
|
|
|
|
|
|
| Symbol
|
Limits
| Unit
|
| Inspection 1/
|
MIL-STD-750
|
|Method |
Conditions
|
| Min
| Max
|
|
|
|
|
|
|
|
|
|
| Subgroup 1
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Visual and mechanical
| 2071
|
|
|
|
|
|
| examination
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Subgroup 2
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| °C/W
| Thermal impedance
| 3101
| See 4.4.1
| ZθJX
|
|
|
|
|
| 1N6686, 1N6687
|
|
| 3.8
|
|
|
|
| 1N6686US, 1N6687US
|
|
| 3.3
|
|
|
|
|
|
|
|
|
|
| IR = 100 µA dc; pulsed (see 4.5.1)
| Breakdown voltage
| 4022
| VBR
|
|
| V dc
|
|
|
| 1N6686, 1N6686US
|
| 100
|
|
|
|
|
| 1N6687, 1N6687US
|
| 200
|
|
|
|
|
|
|
|
|
|
|
| Forward voltage
| 4011
| IF = 5 A (pk); pulsed (see 4.5.1)
| VF1
|
| 0.78
| V dc
|
|
|
| IF = 20 A (pk); pulsed (see 4.5.1)
| VF2
|
| 0.875
| V dc
|
|
|
| IF = 70 A (pk); pulsed (see 4.5.1)
| VF3
|
| 1.0
| V dc
|
|
|
|
|
|
|
|
|
| µA dc
| Reverse current
| 4016
| DC method; VR = rated VR
| IR1
|
| 50
|
| leakage
|
| (see 1.3); pulsed (see 4.5.1)
|
|
|
|
|
|
|
|
|
|
|
|
|
| Subgroup 3
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| TC = +100°C
| High temperature
|
|
|
|
|
|
| operation:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Reverse current
| 4016
| DC method; VR = rated VR
| IR2
|
| 10
| mA dc
|
| leakage
|
| (see 1.3); pulsed (see 4.5.1)
|
|
|
|
|
|
|
|
|
|
|
|
|
| TA = -65°C
| Low temperature
|
|
|
|
|
|
| operation:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Forward voltage
| 4011
| IF = 5 A (pk); pulsed (see 4.5.1)
| VF4
|
| 1.0
| V dc
|
|
|
|
|
|
|
|
|
| Subgroup 4
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Scope display
| 2/
|
|
|
|
|
|
| evaluation
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Reverse recovery time
| 4031
| Condition B; IF = .5 A, IR = 1 A IRR = .25 A | trr
|
| 40
| ns
|
|
|
|
|
|
|
|
|
| Junction capacitance
| 4001
| VR = 10 V dc, f = 1 MHz
| CJ
|
| 350
|
|
|
|
| VSIG = 50 mV (p-p) (maximum)
|
|
|
|
|
| Subgroups 5, 6, and 7
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Not applicable
|
|
|
|
|
|
|
1/ For sampling plan, see MIL-PRF-19500.
2/ The reverse breakdown characteristics shall be viewed on an oscilloscope with display calibration factors of 20 to 50 µA/division and
20 to 200 V/division. Reverse current over the knee shall be at least 100 µA. Each device may exhibit a slightly rounded characteristic
and any discontinuity or dynamic instability of the trace shall be cause for rejection.