MIL-S-19500/254B
* TABLE II. Group E inspection for (all quality levels) for qualification or re-qualification only.
Inspection |
MIL-STD-750 |
Sampling plan |
|
Method |
Conditions |
||
Subgroup 1 Temperature cycling Electrical measurements Subgroup 2 Steady-state operating life 1N1147 1N1149 Electrical measurements Subgroup 4 Thermal impedance curves Subgroup 5 Barometric pressure 1N1147 1N1149 Subgroup 6 ESD |
1051 1026 1001 1020 |
500 cycles See table I, subgroup 2 TC = +100°C, I0 = 45 mA dc, f = 60 Hz VR = 8.4 kV VR = 11.2 kV See table I, subgroup 2 Each supplier shall submit their qual-lot average and design maximum thermal impedance curves. In addition, the optimal test conditions and ZeJX limit shall be provided to the qualifying activity in the qualification report. Pressure = 140 mmHg Pressure = 225 mmHg |
12 devices c = 0 12 devices c = 0 15 devices c = 0 3 devices |
6