MIL-PRF-19500/157T
TABLE II. Group D inspection.
Pre-irradiation
Post-irradiation
VZ1
limits
limits
pre-post
MIL-STD-750
Inspection
irradiation
Symbol
Unit
M, D, R, L, F,
M, D, R, L, F,
1/
change
G, and H
G, and H
Method
Conditions
Min
Max
Min
Max
Min
Max
Subgroup 1
Not applicable
TC = +25C
Subgroup 2
Steady-state total
1019
IZ = 7.5 mA dc,
dose irradiation
0.01 mA dc,
condition A
Reference
4022
IZ = 7.5 mA dc,
VZ
11.12
12.28
11.12
12.28
V dc
voltage
0.01 mA dc
(see 4.5.3)
Small-signal
4051
IZ = 7.5 mA dc,
ZZ
30
30
ohms
breakdown
0.01 mA dc
impedance
Isig = 0.75 ac
A
Reverse current
4016
DC method;
IR
15.0
15.0
leakage
VR = 8.0 V dc
VZ
Voltage stability
4022
IZ = 7.5 mA dc,
(see 4.5.1)
0.01 mA dc,
TA = +25C,
2C
5.0
1N941B-1,
mV
1N941BUR-1
4.0
1N943B-1,
mV
1N943BUR-1
3.0
1N944B-1,
mV
1N944BUR-1
2.0
1N945B-1,
mV
1N945BUR-1
1.5
1N946B-1,
mV
1N946BUR-1
1/ For sampling plan, see MIL-PRF-19500.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business