MIL-PRF-19500/168K
TABLE II. Groups A, B, and C electrical end-point inspection measurements. 1/ 2/
Step
Inspection
Symbol
Limits
Unit
Method
Conditions
Min
Max
IRRM1
1.
Reverse blocking
4211
AC method, bias condition D;
1
mA (pk)
f = 60 Hz; VRRM = rated (see 1.4.1)
cutoff current
IDRM1
1
mA (pk)
2.
Forward blocking
4206
AC method, bias condition D;
f = 60 Hz; VDRM = rated (see 1.4.1)
current
IRRM2
2
mA (pk)
3.
Reverse blocking
4211
AC method, bias condition D;
TC = +125°C minimum; f = 60 Hz;
cutoff current
VRRM = rated (see 1.4.1)
IDRM2
2
mA (pk)
4.
Forward blocking
4206
AC method; bias condition D;
TC = +125°C minimum; f = 60 Hz;
current
VDRM = rated (see 1.4.1)
V2 = VD = 6 V dc; RL = 50 Ω;
VGT1
5.
Gate trigger
2
V dc
4221
voltage and
Re = 20 Ω maximum
IGT1
15
current
mA dc
VTM
ITM = 14.8 A(pk) (pulse);
1.85
V (pk)
4226
6.
Forward "on"
voltage transfer
pulse width = 8.5 ms maximum;
ratio
duty cycle = 2 percent maximum
1/ The electrical measurements for table E-VIB (JAN, JANTX and JANTXV) of MIL-PRF-19500 are as follows:
Subgroups 2, 3, and 6, see table II herein, steps 1, 2, 3, 4, 5, and 6.
2/ The electrical measurements for table E-VII of MIL-PRF-19500 are as follows: Subgroups 2, 3, and 6, see table II
herein, steps 1, 2, 3, 4, 5, and 6.