4.5 Method of inspection. Methods of inspection shall be as specified in appropriate tables and as follows.
4.5.1 Pulse measurements. Conditions for pulse measurements shall be as specified in section 4 of
MIL-STD-750.
*
4.5.2 Delta requirements. Delta requirements shall be as specified below:
Step
Inspection
MIL-STD-750
Symbol
Limit
Unit
Method
Conditions
ĆICB02
1
Collector-base cutoff current
3036
Bias condition D,
100 percent of initial
value or 5 nA dc,
(1)
VCB = 60 V dc
whichever is greater.
±25 percent change
ĆhFE3
2
Forward current transfer
3076
VCE = 10 V dc;
ratio
from initial reading.
(1)
IC = 150 mA dc;
pulsed see 4.5.1
(1) Devices which exceed the group A limits for this test shall not be accepted.