MIL-PRF-19500/385H
* TABLE III. Group E inspection (all quality levels) for qualification or re-qualification only.
Inspection
MIL-STD-750
Sample
plan
Method
Conditions
Subgroup 1
45 devices
c=0
Temperature cycling
1051
500 cycles.
Hermetic seal
1071
Fine leak
Test conditions G or H
Gross leak
Test conditions C or D
End-point electrical
See table I, subgroup 2 and table II herein.
measurements
45 devices
Subgroup 2
c=0
Test temperature = +125C, VGS or VDG = 80 percent
Blocking life
1048
of rated, T = 1,000 hours.
End-point electrical
See table I, subgroup 2 and table II herein
measurements
Subgroup 4 and 5
Not applicable
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business