MIL-PRF-19500/424B
* TABLE II. Group E inspection (all quality levels) for qualification only.
Sampling
MIL-STD-750
plan
Inspection
Method
Conditions
22 devices
Subgroup 1
c=0
Temperature cycling
1051
500 cycles; condition C
Electrical measurement
See table I, group A, subgroup 2
Subgroup 2
22 devices
c=0
1038
1,000 hours, condition A
Steady-state dc blocking
life
Electrical measurement
See table I, group A, subgroup 2
Subgroup 3
Not applicable
Subgroup 4
Sample size
N/A
Thermal impedance curves
See MIL-PRF-19500.
Subgroup 5
10 devices
c=0
Barometric pressure
1001
Pressure = 8.0 mm
1N5188 and 1N5190 only
VR = rated (see 1.3)
10