MIL-PRF-19500/446E
TABLE I. Group A inspection.
Symbol
Unit
MIL-STD-750
Limits
Inspection 1/
Method
Conditions
Min
Max
Subgroup 1
2071
Visual and mechanical
inspection
Subgroup 2
C/W
ZJX
See 4.5.3
3101
1.5
Thermal impedance/leg
Forward voltage/leg
4011
IF = 39 A dc (pk), tp = 8.3 ms;
VF1
0.9
1.40
V (pk)
duty cycle 2 percent
A dc
IR1
2.0
Reverse current/leg
4016
DC method; VR = rated VRWM
(see 1.3)
IR = 50 A dc
4021
V(BR)1
Breakdown voltage/leg
V dc
110
SPA25
V dc
220
SPB25
V dc
440
SPC25
V dc
660
SPD25
Subgroup 3
TC = 100C
High temperature
operation:
A dc
IR2
Reverse current/leg
4016
DC method; VR = rated VRWM
150
(see 1.3)
TA = -55C
Low temperature operation:
A dc
IR3
Reverse current/leg
4016
DC method; VR = rated VRWM
50
(see 1.3)
Subgroup 4
s
Condition B; IF = 0.5 A,
4061
2.5
Reverse recovery time/leg
trr
IR = 1.0 A, Irec = 0.25 A
Subgroups 5 and 6
Not applicable
1/ For sampling plan, see MIL-PRF-19500.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business