MIL-PRF-19500/467A
4.4.3.1 Group C inspection, table E-VII of MIL-PRF-19500.
Subgroup
Method
Condition
2
1056
Test condition A.
2
2036
Test condition E.
2
1071
Fine leak: Test condition G or H (for condition H, leak testing 2 hours after
pressurization is acceptable).
Gross leak: Test condition A, C, D, E, J, or K except that leak indicator fluid
shall be maintained at +100°C ±5°C.
3
2016
Nonoperating; 1,500 G's; t = 0.5 ms; 5 blows in each orientation: X1, Y1, and
Y2.
3
2056
Nonoperating.
3
2006
Nonoperating; 20,000 G's; X1, Y1, and Y2, one minute in each orientation.
IF = 50 mA dc; TA = +25°C, 1,000 hours.
6
1026
Peak forward pulse current (transient); tP = 1 μs, pps = 300, total test time =
7
5 s, Iprt = 1.0 A (pk)
tP = 0.5 ms, PFM ≤ 150 mW, TA = +25°C, IP = 60 mA, 500 hours.
8
4.5 Methods of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows.
4.5.1 Axial luminous intensity. This measurement is made with a photometer.