MIL-PRF-19500/498E
* TABLE I. Group A inspection - Continued.
MIL-STD-750
Limits
Inspection 1/
Conditions
Symbol
Unit
Method
Min
Max
Subgroup 5
TC = +25°C t = 1 s; 1 cycle;
Safe operating area (dc
3051
operation)
(See figures 11 and 12)
Test 1
(All device types)
VCE = 15.6 V dc; IC = 8 A dc
Test 2
VCE = 37 V dc; IC = 3.4 A dc
(All device types)
Test 3
2N6306, 2N6306T1, 2N6306T3
VCE = 200 V dc; IC = 65 mA dc
2N6308, 2N6308T1, 2N6308T3
VCE = 300 V dc; IC = 25 mA dc
Electrical measurements
Table I, subgroup 2 herein
Subgroups 6 and 7
Not applicable
1/
For sampling plan see MIL-PRF 19500.
2/
This test required for the following end-point measurements only:
Group B, subgroups 2 and 3 (JAN, JANTX, and JANTXV).
Group C, subgroups 2 and 6.
Group E, subgroup 1.
11
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business