MIL-PRF-19500/500E
TABLE III. Groups B and C electrical and delta measurements. 1/ 2/ 3/
Unit
Symbol
Step
Inspection
MIL-STD-750
Limits 4/
Min
Max
Method
Conditions
A dc
ID
Column 5
1.
Standby current
4016
DC method, VR = VWM
(column 4 of table II)
tp 300 ms, duty cycle 2
2.
Breakdown voltage
4022
VBR
Column 2
Column 2
V dc
percent, IBR = column 3 of
table II
ID
100 percent of
3.
Standby current
4016
DC method; VR = VWM
initial reading or
(column 4 of table II)
20 percent of
column 5 of table
II, whichever is
greater.
tp 300 ms, duty cycle 2
VBR
4.
Breakdown voltage
4022
± 5 percent of
initial value
percent, IBR = column 3 of
table II
VC
Column 6
V (pk)
5.
Clamping voltage
tp = 1.0 ms (see 4.5.2.a);
IPP = column 7 of table II
1/ The electrical measurements for table E-VIb (JAN, JANTX, and JANTXV) of MIL-PRF-19500 are as follows:
a. Subgroup 2, see table III herein, steps 1 and 2.
b. Subgroup 6, see table III herein, steps 1, 2, 3, and 4.
2/ The electrical measurements for table E-VII (JAN, JANTX, and JANTXV) of MIL-PRF-19500 are as follows:
a. Subgroup 2 and 3, see table III herein, and steps 1 and 2.
b. Subgroup 9, see table III herein, steps 1 and 2 for all levels.
3/ Column references are to table II.
4/ Devices which exceed the table I limits for this test shall not be accepted.