MIL-PRF-19500/544H
TABLE II. Group D inspection.
Inspection 1/ 2/ 3/
Limit
Unit
Method
Conditions
Symbol
Min
Max
Subgroup 1 4/
Neutron irradiation
1017
Neutron exposure VCES = 0V
Breakdown voltage, collector to
3011
80
V dc
V(BR)CEO
Bias condition D, IC = 100 mA dc;
emitter
µA dc
Collector to emitter cutoff
3041
2.0
Bias condition C, VCE = 60 V dc;
ICES1
current
VBE = 0
Collector to emitter cutoff
3041
2.0
mA dc
Bias condition C, VCE = 100 V dc;
ICES2
current
VBE = 0
µA dc
Collector to emitter cutoff
3041
Bias condition D;
100
ICEO
current
VCE = 40 V dc, IB = 0
µA dc
Emitter to base cutoff current
3061
Bias condition D, VEB = 4 V dc,
2.0
IEBO1
IC = 0
Emitter to base cutoff current
3061
2.0
mA dc
Bias condition D, VEB = 5.5 V dc,
IEBO2
IC = 0
Forward-current transfer ratio
3076
VCE = 5 V dc; IC = 50 mA dc
[hFE1] 5/
2N5152
[10]
2N5154
[25]
Forward-current transfer ratio
3076
[hFE2] 5/
VCE = 5 V dc; IC = 2.5 A dc,
Pulsed
2N5152
[15]
90
2N5154
[35]
200
Forward-current transfer ratio
3076
[hFE3] 5/
VCE = 5 V dc; IC = 5 A dc,
pulsed
2N5152
[10]
2N5154
[20]
Base-emitter voltage
3066
1.45
V dc
Test condition B, VCE = 5 V dc,
VBE
(nonsaturated)
IC = 2.5 A dc, pulsed (see 4.5.1)
Base-emitter saturation voltage
3066
Test condition A, IC = 2.5 A dc,
1.67
V dc
VBE(sat)1
Base-emitter saturation voltage
3066
Test condition A, IC = 5 A dc,
2.53
V dc
VBE(sat)2
See footnotes at end of table.
17
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business