MIL-PRF-19500P
APPENDIX E
E.5 SCREENING
E.5.1 Screening. All JANS, JANTXV, and JANTX semiconductor devices (100-percent) shall have been subjected
to, and passed, all the applicable screening tests (as specified in table E-IV) in the sequence shown and the
applicable percent defective allowed (PDA) for the type of semiconductor and quality level (device class) specified.
Devices which fail any test criteria in the screening flow shall be identified and controlled until removal from the lot. At
the option of the manufacturer, the rejects may continue processing to allow the manufacturer to maintain traceability.
The lot records shall identify the point of failure and the actual percent defective (PD) (as applicable). Any rejected
devices shall be removed from the lot prior to shipment. Manufacturers shall have a procedure to address screening
failures. Screening failures should be evaluated as necessary to determine root cause of failure to provide a means
for continuous improvement. Except for JANS, the conditioning and screening tests performed as standard
production tests need not be repeated when these are predesignated and acceptable to the qualifying activity as
being equal to or more severe than specified herein provided the relative process conditioning sequence is
maintained. All tests, preconditioning and screening operations, which were performed on the devices submitted for
qualification inspections specified herein shall be performed on all devices subsequently submitted for conformance
inspection (see E.6).
E.5.2 Percent defective allowable (PDA). Selected electrical parameters shall be designated in the specification
sheet for screen 11 and 13, of table E-IV which shall be used for the PDA calculation. These parameters may also
be compared to determine whether the change during burn-in (delta) is indicative of a lot stability problem. All burn-in
pre-conditioning failures, either high temperature reverse bias (HTRB) or power burn-in, shall be counted towards the
applicable PD unless the pre-conditioning is part of the manufacturer's qualified flow. A lot which fails PDA shall be
subjected to an engineering evaluation.
E.5.2.1 JANTX and JANTXV PDA. The PDA for each inspection lot (or screening lot if the alternate flow is used)
shall be 10 percent (for each burn-in) on all failures for the specified electrical parameters in screens 11 and 13a of
table E-IV. Delta limits shall be defined in the specification sheets. For delta limits, the delta parameter values
measured after burn-in (100-percent screening test) shall be compared with delta parameter values measured prior to
that burn-in. Unless otherwise specified, inspection lots which exceed the 10 percent PDA may be resubmitted one
time only to the burn-in operation failed. The PDA shall be 3 percent on the resubmitted inspection lot to each failed
burn-in. If the combined burn-in PD's for the first submission exceeds 20 percent, or either of the resubmitted burn-in
exceed the 3 percent PDA, the entire lot shall be unacceptable for any quality level.
E.5.2.2 JANS PDA. The PDA for each inspection lot shall be 5 percent (for each burn-in) on all failures for
specified electrical parameters in screens 11 and 13a of table E-IV. Delta limits shall be defined in the specification
sheets. For PDA delta limits, the delta parameter values measured after burn-in (100-percent screening test) shall be
compared with delta parameter values measured prior to that burn-in. Unless otherwise specified, inspection lots
which exceed the 5 percent PDA may be resubmitted one time only to the burn-in operation failed. The PDA shall be
3 percent on the resubmitted inspection lot to each failed burn-in. If the combined burn-in PD for the first submission
exceeds 10 percent, or either of the resubmitted burn-in exceed the 3 percent PDA, the entire inspection lot shall be
unacceptable for any quality level. A lot which fails the PDA shall be subjected to an engineering evaluation.
E.5.3 JANTX and JANTXV product. The procedure for testing and screening for JANTXV and JANTX devices
shall be in accordance with tables E-IV, E-V, E-VIB, E-VII, figure E-1, and as specified in the applicable specification
sheet.
87