MIL-PRF-19500P
APPENDIX G
G.4.3.2 Facility. JANHC qualification shall only be granted to a manufacturer who has a MIL-PRF-19500 certified
facility(basic plant). JANKC qualification will only be granted to a manufacturer who is MIL-PRF-19500 certified to
manufacture JANS products.
G.4.4 Performance characteristics. The electrical performance characteristics of semiconductor die shall be as
specified in the specification sheet.
G.4.5 Critical interfaces. The critical interfaces and physical dimensions of the semiconductor die shall be in
accordance with the requirements of MIL-PRF-19500 and with G.4.5.1 through G.4.5.3. A completed DLA Land and
Maritime Form 36D and die topography, including dimensions, pad locations, and metallization descriptions (die map)
shall be made available for inspection to the qualifying activity prior to qualification. A unique critical interface
identifier as part of the PIN shall be assigned based on any of the following differences:
a.
Bond pad metal.
b.
Backside metal.
G.4.5.1 Bonding pad. The bonding pad size, location, and electrical function shall be in accordance with the
applicable specification sheet. Unless approved by the qualifying activity, the minimum bond pad dimensions shall be
3 mils.
G.4.5.1.1 Metallization integrity. The bonding pads shall be metallized and suitable for bonding as specified in the
applicable specification sheet and shall meet the requirements of G.5.2.5.1.
G.4.5.2 Backing material. The backing material shall be as described in the specification sheet and meet the
requirements of G.5.2.5.2.
G.4.5.3 Glassivation. Glassivation requirements of H.3.7 apply.
G.5 VERIFICATION PROVISIONS
G.5.1 General. EE of semiconductor die shall be performed at a facility with MIL-STD-750 laboratory suitability for
the applicable test methods.
G.5.1.1 Responsibility for inspection. The supplier shall be responsible for the performance of all inspection
requirements as specified herein and in the specification sheet.
G.5.1.2 Retention of records. The supplier shall maintain adequate records of all examinations, inspections, and
tests performed in accordance with the requirements specified herein and the specification sheet. Records, including
variables data, shall be retained in accordance with appendix D.
G.5.1.3 JANKC wafer lot inspection. For JANKC, the process monitors of D.3.9.4 shall apply.
G.5.1.4 Sequence of testing. Subgroups within a group of tests (see table G-II) may be performed in any
sequence, but individual tests within a subgroup shall be performed in the sequence indicated.
G.5.1.5 Sample selection. Samples shall be randomly drawn from inspection lots. The sample size columns in
the evaluation tables give minimum quantities to be evaluated with applicable accept number enclosed in
parenthesis.