MIL-PRF-19500P
APPENDIX E
E.3.5 Nondestructive tests. Unless otherwise demonstrated, the following MIL-STD-750 tests are classified as
nondestructive:
Test
Method number
1001
Barometric pressure (reduced).
1022
Resistance to solvents.
1026, 1027
Steady-state operation life.
1031, 1032
High temperature life (non-operating).
1038, 1039, 1040
Burn-in screen.
1042 (conditions A, B, and C)
Burn-in and life test for power MOSFETs or insulated gate bipolar
transistors (IGBT).
1048
Blocking life.
1051 (100 cycles or less)
Temperature cycling (air to air).
1071
Hermetic seal.
1081
Dielectric withstanding voltage
2006
Constant acceleration.
2016
Shock.
2026
Solderability. (if the original lead finish is unchanged and if the
maximum allowable number of reworks is not exceeded).
2052
Particle impact noise detection (PIND) test.
2056
Vibration, variable frequency.
2066
Physical dimensions.
2069, 2070, 2072, 2073, 2074
Internal visual (pre-cap).
2071
Visual and mechanical examination.
2076
Radiographic.
2081
Forward instability shock (FIST).
2082
Backward instability, vibration (BIST).
3051, 3052, 3053, 3474
Safe operating area (SOA) (condition A for test method 3053).
(with limited supply voltage)
3101
Thermal impedance (response) testing of diodes.
3103
Thermal impedance measurements for insulated gate bipolar transistors
(IGBT) (delta gate-emitter on voltage method).
3104
Thermal impedance measurements of GaAs MOSFET (constant current
forward-biased gate voltage method).
3131
Thermal impedance measurements for bipolar transistors (delta base-
emitter voltage method).
3161
Thermal impedance measurements for vertical power MOSFET's (delta
source-drain voltage method).
3181
Thermal resistance for thyristors.
4066
Surge current.
4081
Thermal resistance of lead mounted diodes (forward voltage, switching
method).
When the junction temperature exceeds the device maximum rated junction temperature for any operation or test
(including electrical stress test), these tests shall be considered destructive except under transient surge or
nonrepetitive fault conditions or approved accelerated screening when it may be desirable to allow the junction
temperature to exceed the rated junction temperature. The feasibility shall be determined on a part by part basis and,
in the case where it is allowed adequate sample testing, shall be performed to provide the proper reliability
safeguards.
81
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business