MIL-PRF-19500/287G
* TABLE III. Group E inspection (all quality levels) - for qualification only.
MIL-STD-750
Inspection
Qualification
Method
Condition
45 devices
Subgroup 1
c=0
1051
Test condition C, 500 cycles.
Temperature cycling
(air to air)
Hermetic seal
1071
Fine leak
Gross leak
Electrical measurements
See table I, subgroup 2 and table II herein.
Subgroup 2
45 devices
c=0
Intermittent life
1037
VCB = 10 V dc, 6,000 cycles. Adjust device current, or power,
to achieve a minimum ΔTJ of 100°C.
Electrical measurements
See group A, subgroup 2 and table II herein.
Subgroups 3
Not applicable
Subgroup 4
See MIL-PRF-19500, table E-IX, group E, subgroup 4.
Thermal impedance
curves
Subgroup 5, 6, and 7
Not applicable
Subgroup 8
45 devices
c=0
Reverse stability
1033
Condition B.
11