MIL-PRF-19500/290P
4.3.1 Power burn-in conditions. Power burn-in conditions are as follows: VCB = 10 - 30 V dc. Power shall be
applied to achieve TJ = +135°C minimum using a minimum PD = 75 percent of PT maximum, TA ambient rated as
defined in 1.3. With approval of the qualifying activity and preparing activity, an alternate burn-in flow may be used
for JANTX and JANTXV quality levels. A justification demonstrating equivalence or adequacy is required. In
addition, the manufacturing site's burn-in data and performance history will be essential criteria for burn-in
modification approval.
4.3.2 Thermal impedance. The thermal impedance measurements shall be performed in accordance with
method 3131 of MIL-STD-750 using the guidelines in that method for determining IM, IH, tH, tMD (and VC where
appropriate). The thermal impedance limit used in screen 3c of 4.3 and the subgroup 2 of table I herein shall comply
with the thermal impedance graph in figures 4 and 5 (less than or equal to the curve value at the same tH time) and
shall be less than the process determined statistical maximum limit as outlined in method 3131.
4.4 Conformance inspection. Conformance inspection shall be in accordance with MIL-PRF-19500, and as
specified herein. If alternate screening is being performed in accordance with MIL-PRF-19500, a sample of screened
devices shall be submitted to and pass the requirements of subgroups 1 and 2, of table I herein, inspection only (table
E-VIb, group B, subgroup 1 is not required to be performed again if group B has already been satisfied in accordance
with 4.4.2).
4.4.1 Group A inspection. Group A inspection shall be conducted in accordance with table E-V of
MIL-PRF-19500 and table I herein.
4.4.2 Group B inspection. Group B inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VIa (JANS) of MIL-PRF-19500 and 4.4.2.1 herein. Electrical measurements (end-points)
and delta requirements shall be in accordance with table I, subgroup 2 and 4.5.3 herein. See 4.4.2.2 for JAN,
JANTX, and JANTXV group B testing. Electrical measurements (end-points) and delta requirements for JAN,
JANTX, and JANTXV shall be after each step in 4.4.2.2 and shall be in accordance with table I, subgroup 2 and 4.5.3
herein.
4.4.2.1 Group B inspection (JANS), table E-VIa of MIL-PRF-19500.
Subgroup Method
Condition
VCB = 10 V dc.
B4
1037
VCB = 10 V dc; PD ≥ 100 percent of maximum rated PT (see 1.3). (NOTE: If a failure
B5
1027
occurs, resubmission shall be at the test conditions of the original sample.)
Option 1: 96 hours minimum sample size in accordance with table E-VIA
of MIL-PRF-19500, adjust TA or PD to achieve TJ = +275°C minimum.
Option 2: 216 hours minimum, sample size = 45, c = 0; adjust TA or PD to achieve a
TJ = +225°C minimum.
7