MIL-PRF-19500/407E
* TABLE I. Group A inspection.
Inspection 1/
MIL-STD-750
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 1
Visual and mechanical
2071
examination
Subgroup 2
Thermal impedance
3131
See 4.3.2.
°C/W
ZθJC
Breakdown voltage
3011
70
V dc
Bias condition D, IC = 200 mA dc,
V(BR)CEO
collector to emitter
pulsed (see 4.5.1)
Breakdown voltage
3011
80
V dc
Bias condition B, IC = 200 mA dc,
V(BR)CER
collector to emitter
pulsed (see 4.5.1), RBE = 100 ohms
3011
90
V dc
Breakdown voltage
Bias condition D, IC = 200 mA dc,
V(BR)CEX
collector to emitter
pulsed (see 4.5.1), VBE = -1.5 V dc
1
mA dc
Collector-emitter
3041
Bias condition D,
ICEO
cutoff current
VCE = 60 V dc
1
mA dc
3041
Collector-emitter
ICEX1
Bias condition A, VCE = 100 V dc,
cutoff current
VBE = -1.5 V dc
1
mA dc
Emitter-base cutoff
3061
Base condition D, VEB = 7 V dc
IEBO
current
Forward-current
40
3076
VCE = 4 V dc, IC = 0.5 A dc
hFE1
transfer ratio
Forward-current
20
60
3076
VCE = 4 V dc, IC = 4 A dc, pulsed
hFE2
transfer ratio
(see 4.5.1)
Forward-current
3076
5
VCE = 4 V dc, IC = 10 A dc, pulsed
hFE3
transfer ratio
(see 4.5.1)
3071
Collector-emitter
0.75
V dc
VCE(sat)1
IC = 4 A dc, IB = 0.4 A dc, pulsed
saturated voltage
(see 4.5.1)
Base-emitter
3066
1.4
V dc
Test condition B, VCE = 4 V dc,
VBE
saturated voltage
IC = 4 A dc, pulsed (see 4.5.1)
Collector-emitter
3071
2
V dc
VCE(sat)2
IC = 10 A dc, IB = 3.3 A dc, pulsed
saturated voltage
(see 4.5.1)
See footnote at end of table.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business