MIL-PRF-19500/407E
TABLE II. Groups A, B, C, and E delta measurements. 1/ 2/ 3/
Step
Inspection
MIL-STD-750
Symbol
Limits
Unit
Method
Conditions
Min
Max
±100 percent of initial value or
ĆICEX1
Bias condition A,
3041
Collector to emitter
1.
100 µA dc, which ever is greater
VBE = -1.5 V dc,
cutoff current
VCE = 100 V dc
ĆhFE2
±25 percent change in initial recorded
3076
Forward-current
VCE = 4 V dc, IC = 4 A dc,
2.
transfer ratio
pulsed (see 4.5.1)
value
1/ The delta measurements for table E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500 are: Subgroups 3
and 6, see table II herein, steps 1 and 2.
2/ The delta measurements for table E-VII of MIL-PRF-19500 are: Subgroup 6, see table II herein, steps 1 and 2.
3/ The delta measurements for table E-IX of MIL-PRF-19500 are: Subgroups 1 and 2, see table II herein, all
steps.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business