MIL-PRF-19500/431E
TABLE I. Group A inspection - Continued.
MIL-STD-750
Inspection
1/
Limit
Unit
Symbol
Method
Conditions
Min
Max
Subgroup 3
TA = +150°C
High temperature
operation:
µA dc
Gate current
3411
Bias condition C; VDS = 0 V dc
IGSS2
-0.2
VGS = -20 V dc;
Drain current
3413
VDS = 20 V dc; bias condition A
ID(off)2
VGS = -12 V dc
µA dc
2N4091, UB
0.2
VGS = -8 V dc
µA dc
2N4092, UB
0.2
VGS = -6 V dc
µA dc
2N4093, UB
0.2
Subgroup 4
Small-signal common-
3431
VDS = 20 V dc; VGS = 0;
16
pF
Ciss
source short-circuit input
f = 1 MHz
capacitance
Small-signal common-
3433
VDS = 0 V dc; VGS = 20;
5
pF
Crss
source reverse transfer
f = 1 MHz
capacitance
Turn-on delay time
See figure 3
td(on)
2N4091, UB
15
ns
2N4092, UB
15
ns
2N4093, UB
15
ns
Rise time
See figure 3
tr
2N4091, UB
10
ns
2N4092, UB
20
ns
2N4093, UB
40
ns
Turn-off delay time
See figure 3
td(off)
2N4091, UB
40
ns
2N4092, UB
60
ns
2N4093, UB
80
ns
Subgroups 5, 6, 7
Not applicable
1/ For sampling plan, see MIL-PRF-19500.
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business