MIL-PRF-19500/510J
TABLE II. Group D inspection.
Limits
Inspection 1/ 2/ 3/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 1 4/
Neutron irradiation
1017
Neutron exposure Vces = 0 V
Breakdown voltage,
3011
Bias condition D, IC = 200 mA dc,
V(BR)CEO
collector to emitter
L = 42 mH, f = 30 - 60 Hz (see figure 10)
2N6249, 2N6249T1
200
V dc
2N6249T3
2N6250, 2N6250T1
275
V dc
2N6250T3
2N6251, 2N6251T1
350
V dc
2N6251T3
Breakdown voltage,
3011
Bias condition D, IC = 200 mA dc,
V(BR)CER
collector to emitter
L = 14 mH, f = 30 - 60 Hz,
2N6249, 2N6249T1
225
V dc
2N6249T3
2N6250, 2N6250T1
300
V dc
2N6250T3
2N6251, 2N6251T1
375
V dc
2N6251T3
µA dc
Emitter to base
3061
200
IEBO
Bias condition D, VEB = 6 V dc
cutoff current
Collector to emitter
3041
Bias condition D
ICEO
cutoff current
VCE = 150 V dc
2.0
mA dc
2N6249, 2N6249T1
2N6249T3
VCE = 225 V dc
2.0
mA dc
2N6250, 2N6250T1
2N6250T3
VCE = 300 V dc
2.0
mA dc
2N6251, 2N6251T1
2N6251T3
Collector to emitter
3041
Bias condition A, VBE = -1.5 V dc
ICEX1
cutoff current
µA dc
VCE = 225 V dc
20
2N6249, 2N6249T1
2N6249T3
µA dc
VCE = 300 V dc
20
2N6250, 2N6250T1
2N6250T3
µA dc
VCE = 375 V dc
20
2N6251, 2N6251T1
2N6251T3
See footnotes at end of table.