MIL-PRF-19500/510J
* 4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VII of MIL-PRF-19500. Electrical measurements (end-points) shall be in accordance with
table I, subgroup 2 herein.
Subgroup
Method
Condition
C2
2036
Test condition A; weight - 10 pounds; time - 15 seconds.
Non-operating 1,500 G; 0.5 ms, 5 blows in each orientation: X1, Y1, Y2, Z1
C3
2016
(total 20 blows).
C5
3131
VCB = 10 V dc; TJ = +175°C minimum; TA =+30°C
*
C6
1027
or
maximum.
VCB = 10 V dc, adjust power or current to achieve ĆTJ = +100°C.
1037
4.4.4 Group D inspection. Conformance inspection for hardness assured JANS and JANKC types shall include
the group D tests specified in table II herein. These tests shall be performed as required in accordance with
MIL-PRF-19500 and method 1019 of MIL-STD-750, for total ionizing dose or method 1017 of MIL-STD-750 for
neutron fluence as applicable (see 6.2.e herein), except group D, subgroup 2 may be performed separate from other
subgroups. Group D inspection may also be performed ahead of the screening lot using die selected in accordance
with MIL-PRF-19500 and related documents. Alternate package options may also be substituted for the testing
provided there is no adverse effect to the fluence profile.
4.4.5 Group E inspection. Group E inspection shall be conducted in accordance with the conditions specified for
subgroup testing in appendix E, table E-IX of MIL-PRF-19500 and as specified herein. Electrical measurements
(end-points) shall be in accordance with table I, subgroup 2 herein.
4.5 Methods of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows.
4.5.1 Pulse measurements. Conditions for pulse measurement shall be as specified in section 4 of
4.5.2 Thermal resistance. Thermal resistance measurement shall be conducted in accordance with test method
3131 of MIL-STD-750. The following details shall apply:
a.
Collector current magnitude during power applications shall be 3.0 A dc.
b.
Collector to emitter voltage magnitude shall be 10 V dc.
c.
Reference temperature measuring point shall be the case.
Reference point temperature shall be +25°C ≤ tr ≤ +75°C and recorded before the last is started.
d.
e.
Mounting arrangement shall be with heat sink to header.
f.
4.5.3 Coil selection for safe operating area (SOA) tests. In selecting coils for use in the clamped and unclamped
inductive SOA tests, prime consideration should be given to the recommended commercially available coil. However,
due to the extreme critical nature of the coil in these circuits and the wide tolerance of some commercially available
coils (+100, -50 percent), it shall be the semiconductor manufacturer's responsibility, to prove upon request,
compliance or equivalency of any coil used (commercial or in-plant designed) to within (+20, -10 percent), of the
specified inductance at the rated current and dc resistance.