MIL-PRF-19500/518D
4.5 Methods of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows.
4.5.1 Pulse measurements. Conditions for pulse measurement shall be as specified in section 4 of MIL-STD-750.
4.5.2 Coil selection for safe operating area (SOA) tests. In selecting coils for use in clamped and unclamped
inductive SOA tests, prime consideration should be given to the commercially available coil. However, due to the
extreme critical nature of the coil in these circuits and wide tolerance of some commercially available coils (+100
percent, -50 percent), it shall be the semiconductor manufacturer's responsibility to prove upon request compliance or
equivalency of any coil used (commercial or in-plant designed) to be within (+20 percent, -10 percent) of the specified
inductance at the rated current and dc resistance.