MIL-PRF-19500/518D
* TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Limits
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 2 - Continued
Base to emitter
3066
Test condition B, VCE = 10 V
VBE
1.5
V dc
non-saturated voltage
dc, IC = 1.0 A dc, pulsed (see
4.5.1)
Base to emitter
3066
Test condition A, IC = 1.0 A dc,
VBE(sat)1
1.5
V dc
*
saturated voltage
IB = 0.1 A dc, pulsed (see 4.5.1)
3071
IC = 1.0 A dc, IB = 0.1 A dc,
Collector to emitter
2.5
V dc
VCE(sat)1
saturated voltage
pulsed (see 4.5.1)
1.0
V dc
3071
IC = 0.5 A dc, IB = 0.05 A dc,
VCE(sat)2
Collector to emitter
saturated voltage
pulsed (see 4.5.1)
Forward-current
3076
VCE = 5 V dc, IC = 50 mA dc,
hFE1
30
transfer ratio
pulsed (see 4.5.1)
3076
VCE = 5 V dc, IC = 500 mA dc,
Forward-current
hFE2
40
160
transfer ratio
pulsed (see 4.5.1)
3076
VCE = 10 V dc, IC = 1 A dc,
hFE3
20
Forward-current
transfer ratio
pulsed (see 4.5.1)
Subgroup 3
TA = +150°C
High-temperature
operation:
Collector to emitter
3041
Bias condition A,
ICEX2
cutoff current
VBE = 1.5 V dc
2N3766
1.0
mA dc
VCE = 50 V dc
2N3767
1.0
mA dc
VCE = 70 V dc
TA = -55°C
Low-temperature
operation:
3086
VCE = 5.0 V dc, IC = 0.5 A dc,
hFE4
13
Forward-current
transfer ratio
pulsed (see 4.5.1)
See footnotes at end of table.