MIL-PRF-19500/528B
* TABLE I. Group A inspection.
Inspection 1/
MIL-STD-750
Limit
Unit
Symbol
Method
Conditions
Min
Max
Subgroup 1
2071
Visual and mechanical
examination
Subgroup 2
C/W
Thermal impedance
3131
See 4.3.2
ZJX
*
Breakdown voltage,
IC = 200 mA dc; f = 30 - 60 Hz;
V(BR)CEO
collector to emitter
L = 15 mH (see figure 2)
2N6032
90
V dc
2N6033
120
V dc
Breakdown voltage,
IC = 200 mA dc; f = 30 - 60 Hz;
V(BR)CER
collector to emitter
L = 15 mH (see figure 2)
2N6032
110
V dc
2N6033
140
V dc
Breakdown voltage,
IC = 200 mA dc; f = 30 - 60 Hz;
V(BR)CEX
collector to emitter
L = 2 mH (see figure 2)
2N6032
120
V dc
2N6033
150
V dc
IEBO
Emitter to base cutoff
10
mA dc
3061
Bias condition D
VEB = 7 V dc
current
ICEO
Collector to emitter
10
mA dc
3041
Bias condition D
VCE = 80 V dc
cutoff Current
*
A dc
Collector to emitter cutoff
3041
Bias condition A; VBE = -1.5 V dc
ICEX1
250
Current
2N6032
VCE = 110 V dc
2N6033
VCE = 135 V dc
Collector to base cutoff
3036
Bias condition D;
ICBO
Current
2N6032
VCB = 120 V dc
25
mA dc
2N6033
VCB = 150 V dc
25
mA dc
Forward-current transfer
3076
VCE = 2.6 V dc; IC = 50 A dc
hFE1
ratio
(pulsed see 4.5.1)
2N6032
10
50
Forward-current transfer
3076
VCE = 2.0 V dc; IC = 40 A dc
hFE1
ratio
(pulsed see 4.5.1)
2N6033
10
50