MIL-PRF-19500/528B
* TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Limit
Unit
Symbol
Method
Conditions
Min
Max
Subgroup 2 - Continued
Collector-emitter saturation
3071
IC = 50 A dc; IB = 5.0 A dc;
VCE(sat)
1.3
V dc
voltage
pulsed (see 4.5.1)
2N6032
Collector-emitter saturation
3071
IC = 40 A dc; IB = 4.0 A dc
VCE(sat)
1.0
V dc
voltage
pulsed (see 4.5.1)
2N6033
VBE(sat)
Base-emitter saturation
3306
Test condition A; IB = 5.0 A dc;
2.0
V dc
IC = 50 A dc; pulsed (see 4.5.1)
voltage
2N6032
VBE(sat)
Base-emitter saturation
3306
Test condition A; IB = 4.0 A dc;
2.0
V dc
IC = 40 A dc; pulsed (see 4.5.1)
voltage
2N6033
Subgroup 3
TA = +150C
High temperature operation
ICEX2
3041
Bias condition D;VBE = 1.5 V dc;
Collector to emitter cutoff
VCE = 100 V dc
current
2N6032
15
mA dc
2N6033
10
mA dc
TA = -55C
Low temperature operation
Forward-current transfer
3076
Pulsed (see 4.5.1)
hFE2
ratio
2N6032
VCE = 2.6 V dc; IC = 50 A dc
5
2N6033
VCE = 2.0 V dc; IC = 40 A dc
5
Subgroup 4
VCE = 10 V dc; IC = 2.0 A dc;
/hfe/
10
40
Magnitude of small-signal
3306
f = 5.0 MHz
short- circuit forward current
transfer ratio
Cobo
VCB = 10 V dc; IE = 0;
1,000
pF
Open circuit Output
3236
100 kHz < f < 1 MHz
capacitance
See footnote at end of table.
8