MIL-PRF-19500/545K
4.5 Methods of inspection and test. Methods of inspection and test shall be as specified in the appropriate tables
and as follows.
4.5.1 Pulse measurements. Conditions for pulse measurements shall be as specified in section 4 of
4.5.2 Thermal resistance. Thermal resistance measurements shall be conducted in accordance with
method 3131 of MIL-STD-750. The following details shall apply:
a. Collector current magnitude during power application shall be -500 mA minimum dc.
b. Collector to emitter voltage magnitude shall be -10 V dc.
c. Reference temperature measuring point shall be the case.
d. Reference temperature measuring point shall be within the range +25°C ≤ TR ≤ +35°C. The chosen reference
temperature shall be recorded before the test is started.
e. Mounting arrangement shall be with heat sink to case.