MIL-PRF-19500/552G
TABLE III. Group A, B, and C electrical end-point and delta measurements. 1/ 2/
Limits
Step
Inspection
Symbol
Unit
Method
Conditions
Min
Max
µA dc
1.
Reverse current
4016
DC method, VR = VRWM
ID
Column
5 of
(column 4 of table II)
table II
tp ≤ 300 ms, duty cycle
2.
Breakdown voltage
4022
VBR1
Column 2
V dc
of table II
≤ 2 percent; IBR = column 3
of table II
ĆID
3.
Reverse current
4016
DC method; VR = VRWM
100 percent of
initial reading or
(column 4 of table II)
20 percent of
column 5 of table
II, whichever is
greater.
tp ≤ 300 ms, duty cycle
ĆVBR1
4.
Breakdown voltage
4022
±5 percent of
initial value.
≤ 2 percent; IBR = column 3
of table II
5.
Clamping voltage
tp = 1.0 ms (see 4.5.2.a);
VC
Column 2
V (pk)
of table II
IPP = column 7 of table II
1/
The electrical measurements for table E-VIB (JANTX and JANTXV) of MIL-PRF-19500 are as follows:
a. Subgroup 2, see table III herein, steps 1 and 2.
b. Subgroup 3, see table III herein, steps 1, 2, 3, and 4 (see 4.3.1.c).
c. Subgroup 6, see table III herein, steps 1, 2, 3, and 4.
2/
The electrical measurements for table E-VII of MIL-PRF-19500 are as follows:
a. Subgroup 2, see table III herein, steps 1 and 2.
b. Subgroup 6, see table III herein, steps 1, 2, 3, and 4 (see 4.3.1.c).
c. Subgroup 8, see table III herein, steps 1 and 2.
11