MIL-PRF-19500/564H
* TABLE I. Group A inspection - Continued.
Inspection 1/
MIL-STD-750
Symbol
Limits
Unit
Method
Condition
Min
Max
Subgroup 3
TC = TJ = +125C
High temperature
operation:
200
Bias condition C, VGS = 20 V dc,
nA dc
Gate current
3411
IGSS2
VDS = 0
IDSS2
Drain current
3413
Bias condition C, VGS = 0,
-0.25
mA dc
VDS = 80 percent of rated VDS
VDS VGS, ID = -.25 mA
Gate to source voltage
3403
-1.0
V dc
VGS(th)2
(threshold)
rDS(on)3
Static drain to source
3421
VGS = -10 V dc, pulsed (see 4.5.1),
ID = rated ID2
on-state resistance
2N6849, 2N6849U
0.54
2N6851, 2N6851U
1.60
TC = TJ = -55C
Low temperature
operation:
VDS VGS, ID = -.25 mA
Gate to source voltage
3403
-5.0
V dc
VGS(th)3
(threshold)
Subgroup 4
Switching time test
3472
ID = rated ID1; VGS = -10 V dc; gate
drive impedance = 7.5 ;
Turn-on delay time
td(on)
2N6849, 2N6849U
60
ns
VDD = -40 V dc
2N6851, 2N6851U
50
ns
VDD = -75 V dc
Rise time
tr
2N6849, 2N6849U
140
ns
VDD = -40 V dc
2N6851, 2N6851U
100
ns
VDD = -75 V dc
Turn-off delay time
td(off)
2N6849, 2N6849U
140
ns
VDD = -40 V dc
2N6851, 2N6851U
80
ns
VDD = -75 V dc
Fall time
tf
2N6849, 2N6849U
140
ns
VDD = -40 V dc
2N6851, 2N6851U
80
ns
VDD = -75 V dc
See footnotes at end of table.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business