MIL-PRF-19500/567E
* TABLE I. Group A inspection.
Limits
Inspection 1/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 5
Surge current
4066
IFSM= 80 A(pk), VRM = 45 V(pk), IO = 0.75 A
ten surges of 8.3 ms each at 1 minute intervals,
TA = +25°C
Electrical measurements
See table I, subgroup 2 herein
1/
For sampling plan, see MIL-PRF-19500.
2/
Measurement point is on the lead .2 inch (5.08 mm) below the seating plane of the case.
*
3/
This test required for the following end-point measurements only:
Group B, subgroups 3, 4, and 5 (JANS).
Group B, subgroups 2 and 3 (JAN, JANTX, and JANTXV).
Group C, subgroup 2 and 6.
Group E, subgroup 1.
TABLE II. Groups B and C delta tests. 1/ 2/
Limits
Symbol
Unit
Step
Inspection
Method
Conditions
Min
Max
ĆVFM2
±50 mV change from
1.
Forward voltage
4011
IFM = 4 A(pk) pulsed
V
previous value
(see 4.5.1)
ĆIRM1
+500 µA dc or +100
2
Reverse current
4016
VRM = 45 V(pk)
mV
percent of initial value,
pulsed (see 4.5.1)
whichever is greater
1/ The delta measurements for table E-VIA (JANS) of MIL-PRF-19500 are as follows: Subgroups 4 and 5, see table
II herein, steps 1 and 2.
2/ The delta measurements for table E-VII of MIL-PRF-19500 are as follows: Subgroup 6, see table II herein, steps
1 and 2.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business