MIL-PRF-19500/567E
* TABLE I. Group A inspection.
Limits
Inspection 1/
Symbol
Unit
Method
Conditions
Min
Max
Subgroup 1
Visual and mechanical
2071
inspection
Subgroup 2
2/
°C/W
*
Thermal impedance 3/
3101
See 4.3.2
ZϴJX
or 4081
Forward voltage
4011
IFM = 4.0 A(pk), pulsed (see 4.5.1)
VFM2
0.68
V
*
4011
IFM = 2.0 A(pk), pulsed (see 4.5.1)
VFM3
0.56
V
4011
IFM = 1.0 A(pk), pulsed (see 4.5.1)
VFM4
0.48
V
4011
IFM = 8.0 A(pk), pulsed (see 4.5.1)
VFM1
0.92
V
Reverse current leakage
4016
VRM = 45 V(pk), pulsed method, (see 4.5.1)
IRM1
2.0
mA
Subgroup 3
2/
TA = +125°C
High temperature operation
Reverse current leakage
4016
VRM= 45 V(pk), pulsed method, (see 4.5.1)
IRM2
20
mA
TA = +175°C
High temperature operation
Reverse current leakage
4016
VRM= 45 V(pk), pulsed method, (see 4.5.1)
IRM3
200
mA
TA = -55°C
Low temperature operation
Reverse current leakage
4016
VRM = 45 V(pk), pulsed method, (see 4.5.1)
IRM4
20
mA
Forward voltage
4011
IFM = 2.0 A(pk), pulsed (see 4.5.1)
VFM5
0.63
V
Subgroup 4
Reverse current leakage at
4016
Pulsed method (see 4.5.1), VRSM = 54 V(pk),
IRM5
2.0
A
peak reverse voltage
(alternate test, see 4.5.4) 2/
VR = 5 V, .01 ≤ f ≤ 1 MHz, VSIG = 15 mV(p-p)
Capacitance
4001
CT
450
pF
Scope display evaluation
4023
Sharp and stable (see 4.5.5), n = 116, c = 0
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business