MIL-PRF-19500/589A
TABLE I. Group A inspection.
Inspection 1/
MIL-STD-750
Symbol
Limits
Unit
Method
Conditions
Min
Max
Subgroup 1
Visual and mechanical
2071
Subgroup 2
Breakdown voltage,
3407
600
V
VGE = 0; IC = 1.0 mA
VBR(CES)
collector to emitter
bias condition C
Gate to emitter
3403
3.0
5.5
V dc
VCE
VGE; IC = 0.25 mA
VGE(th)1
voltage (threshold)
Gate current
3411
100
nA dc
VGE = 20 V; VCE = 0 V
IGESF1
bias condition C
Gate current
3411
-100
nA dc
VGE = -20 V; VCE = 0 V
IGESR1
bias condition C
250
A dc
Collector current
3413
Bias condition C; VGE = 0 V
ICES1
VCE = 80 percent of rated VCE
Static collector to emitter
3405
3.0
V
VGE = 15 V; IC = IC2
VCE(on)1
on-state voltage
condition A; pulsed (see 4.5.1)
Static collector to emitter
3405
3.25
V
VGE = 15 V; IC = IC1
VCE(on)2
on-state voltage
condition A; pulsed (see 4.5.1)
Forward voltage
4011
1.7
V
VG = 0; IF = IC2
VF
Subgroup 3
High temperature operation:
TC = TJ = +125 C
500
nA dc
Gate current
3411
Bias condition C,
IGES
VGE = 20 V; VCE = 0 V
-500
nA dc
Gate current
3411
Bias condition C,
IGES
VGE = 20 V; VCE = 0 V
5.0
mA dc
Collector current
3413
Bias condition C, VGE = 0
ICES2
VCE = 100 percent of rated VCE
Gate to emitter voltage
3403
2.0
V dc
VCE
VGE
VGE(th)
(threshold)
IC = 0.25 mA
See footnote at end of table.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.