MIL-PRF-19500/589A
TABLE III. Groups A, B, C, and E electrical end-point measurements. 1/ 2/ 3/
Step
Inspection
MIL-STD-750
Symbol
Limits
Unit
Method
Conditions
Min
Max
1.
Breakdown voltage,
3407
600
V dc
VGE = 0; IC = 1.0 mA
VBR(CES)
collector to emitter
bias condition C
2.
Gate to emitter
3403
3.0
5.5
V dc
VCE
VGE
VGE(th)1
voltage (threshold)
IC = 0.25 mA
3.
Gate current
3411
100
nA dc
VGE = 20 V; VCE = 0
IGES
bias condition C
-100
nA dc
Gate current
3411
VGE = 20 V; VCE = 0
IGES
bias condition C
250
A
4.
Collector current
3413
VGE = 0
ICES
bias condition C
VCE = 80 percent of
rated VCE
3.0
V
5.
Static collector to emitter
3413
VGE = 15 V
VCE(on)1
on-state voltage
Condition A, pulsed
(see 4.5.1)
IC = IC1
3.25
V
6.
Static collector to emitter
3405
VGE = 15 V
VCE(on)2
on-state voltage
condition A, pulsed
(see 4.5.1), IC = IC1
1.7
V
7.
Forward voltage drop
4011
VG = 0; IF = IC2
VF
8.
Thermal response
3103
See 4.5.4
3101
1/ The electrical measurements for appendix E, table VII of MIL-PRF-19500 are as follows:
a.
Subgroups 3 and 4, see table III herein, steps 1, 2, 3, 4, 5, 6, 7, and 8.
b.
Subgroups 5 and 6, see table III herein, steps 1, 2, 3, 4, 5, 6, and 7.
2/ The electrical measurements for appendix E, table VIb (JANTX and JANTXV) of MIL-PRF-19500 are as follows:
Subgroups 2 and 3, see table III herein, steps 1, 2, 3, 4, 5, 6, 7, and 8.
3/ The electrical measurements for appendix E, table VII of MIL-PRF-19500 are as follows:
a.
Subgroups 2 and 3, see table III herein, steps 1, 2, 3, 4, 5, 6, and 7.
b.
Subgroup 6, see table III herein, steps 1, 2, 3, 4, 5, 6, 7, and 8.
13
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.