MIL-PRF-19500/609K
4.4.2.2 Group B inspection, table E-VIB (JAN, JANTX, and JANTXV) of MIL-PRF-19500. Leaded samples from
the same lot may be used in lieu of `US' suffix sample for life test.
Subgroup Method
Conditions
0°C to + 100°C, 10 cycles.
B2
1056
-55°C to +175°C, 45 cycles including screening.
B2
1051
B3
1027
V(pk) = rated VRWM; f = 50 - 60 Hz; IO = 300 mA dc minimum; adjust TA or IO to obtain a
minimum TJ of +150°C. (See 4.5.1)
B4
2101
Decap analysis; scribe and break only
TA = +175°C.
B6
1032
4.4.3 Group C inspection. Group C inspection shall be conducted in accordance with the conditions specified for
subgroup testing in table E-VII of MIL-PRF-19500 and as folows. Electrical measurements (end-points) shall be in
accordance with table I, subgroup 2 herein.
* 4.4.3.1 Group C inspection, table E-V of MIL-PRF-19500.
Subgroup Method
Condition
0°C to + 100°C, 10 cycles.
C2
1056
-55°C to + 175°C, 45 cycles including screening.
C2
1051
*
C2
2036
Axial devices - Tension: Condition A, 6 pounds, t = 15 s. Fatigue: Condition E. NOTE: Not
applicable to US versions.
*
C2
2038
US devices - Condition B, 6 pounds, t = 15s.
L = .375 inch (9.53 mm), RθJL = 150°C/W maximum; RθJEC = 40°C/W; (see 4.3.3).
C5
4081
C6
1026
1,000 hours minimum, V(pk) = rated VRWM; f = 50 - 60 Hz; IO = 300 mA dc minimum;
adjust TA or IO to obtain a minimum TJ of +150°C. (See 4.5.1)
4.4.4 Group E inspection. Group E inspection shall be conducted in accordance with the tests and conditions
specified for subgroup testing in table E-IX of MIL-PRF-19500 and table II herein. Electrical measurements (end-
points) shall be in accordance with table I, subgroup 2 herein.
4.5 Methods of inspection. Methods of inspection shall be as specified in the appropriate tables and as follows.
4.5.1 Free air power burn-in and life tests. The use of a current limiting or ballast resistor is permitted provided
that each device under test still sees the full Pt (minimum) and that the minimum applied voltage, where applicable,
maintained through-out the burn-in period. Method 3100 of MIL-STD-750 shall be used to measure TJ.
10