MIL-PRF-19500/169N
TABLE II. Group E inspection (all quality levels) for qualification and requalification only.
MIL-STD-750
Qualification
Inspection
inspection
Method
Conditions
Subgroup 1
n = 45, c = 0
100 cycles 0°C to 100°C
Thermal shock (glass strain)
1056
500 cycles, -65°C to +175°C
Temperature cycling
1051
Hermetic seal
1071
Gross leak only
Electrical measurement
See table I, subgroup 2
Subgroup 2
10,000 cycles
Intermittent operating life
1037
See table I, subgroup 2
Electrical measurements
Subgroup 4
Thermal impedance curves
See MIL-PRF-19500
Subgroup 5
Not applicable
n=3
Subgroup 6
1020
ESD
n = 45
Subgroup 8
1057
Test condition B. Test until failure occurs or to a
Resistance to glass cracking
maximum of 25 cycles, whichever comes first.
n = 22, c = 0
Subgroup 9
1055
Monitored mission
temperature cycling
See table I, subgroup 2
Electrical measurements