MIL-PRF-19500/317R
TABLE III. Groups B, C, and E delta measurements.
Step
Inspection 1/ 2/ 3/ 4/
MIL-STD-750
Symbol
Limit
Method
Conditions
ĆhFE3
±25 percent change from
1.
Forward-current
3076
VCE = 1.0 V dc; IC = 10 mA
transfer ratio
dc; pulsed (see 4.5.1)
initial value.
ĆVCE(sat)1
±50 mV change from
2.
Collector - emitter
3071
IC = 10 mA dc
and resistance
IB = 1.0 mA dc
previous measured value.
ĆICES
3.
Collector - emitter
3041
Bias condition C;
100 percent of initial value or
cutoff current
VCE = 20 V dc
25 nA dc, whichever is greater.
1/
The delta measurements for table E-VIa (JANS) of MIL-PRF-19500 are as follows: Subgroups B4 and B5, see
table III herein, steps 1, 2, and 3.
The delta measurements (JAN, JANTX, and JANTXV) of 4.4.2.2 herein are as follows: Steps 1, 2, and 3, see
2/
table III herein, steps 1 and 3.
The delta measurements for table E-VII of MIL-PRF-19500 and 4.4.3.1 are as follows: Subgroup 6, see table III
3/
herein, steps 2 and 3 (for JANS).
4/
The delta measurements for table E-IX of MIL-PRF-19500 and table III herein are as follows: Subgroups 1 and
2, see table III herein, all steps.
22